BQXFS - SOLUTION S0121 HTD-1 (BUFFER)

  • MSDS: BQXFS
  • Manufacturer: NALCO CHEMICAL CO
  • Product Name: SOLUTION S0121 HTD-1 (BUFFER)
  • National Stock Number: 6850-00N038181
Product Identification

Product ID:SOLUTION S0121 HTD-1 (BUFFER)
MSDS Date:05/19/1989
FSC:6850
NIIN:00N038181
MSDS Number: BQXFS

Responsible Party
NALCO CHEMICAL CO
ONE NALCO CENTER
NAPERVILLE, IL 60563-1198
US

Emergency Phone: 708-920-1510

Info Phone: 708-920-1510

Preparer: RICKY A. STACKHOUSE

Cage: 89524

Contractor
ONDEO NALCO COMPANY
NAPERVILLE, IL 60563-1198 US

Telephone: (630) 305-1000

Cage: 89524

Ingredients

(ORAL,RAT)

CAS: 141-43-5

RTECS: KJ5775000

Fraction By Weight: 10-20%

OSHA PEL 3 PPM;6 PPM STEL

ACGIH TLV: 3 PPM;6 PPM STEL


IF UNCON,

RTECS: 9999999ZZ


DISP TO SANITARY LANDFILL. CAN BE INCIN

RTECS: 9999999ZZ


PUNCTURED, IF PLASTIC & PLACED IN GARBAGE COLLECTION

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:SEE INGREDIENT 1.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:SKIN/EYE CONTACT:CAN CAUSE MODERATE TO
SEVERE IRRITATION. INGESTION:CAN BE HARMFUL. INHALATION:CAN CAUSE
RESPIRATORY IRRITATION.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:A REVIEW OF AVAILABLE DATA DOES NOT IDENTIFY
ANY SYMPTOMS FROM EXPOSURE.
Medical Cond Aggravated by Exposure:A REVIEW OF AVAILABLE DATA DOES NOT
IDENTIFY ANY WORSENING OF EXISTING CONDITIONS.

First Aid

First Aid:EYES:IMMED FLUSH FOR AT LST 15 MINS WHILE HOLDING EYELIDS
OPEN. CALL MD AT ONCE. SKIN:IMMED FLUSH W/WATER FOR AT LST 15 MINS.
FOR LG SPLASH, FLOOD BODY UNDER SHOWER. CALL MD AT ONCE. INGEST:DO
NOT IND UCE VOMIT. GIVE WATER. CALL MD. INHAL:REMOVE TO FRESH AIR.
TREAT SYMPS. CALL MD. NOTE TO MD:NO SPECIFIC ANTIDOTE IS KNOWN.
BASED ON INDIVIDUAL RXNS OF PATIENT, MD'S JUDGMENT SHLD BE USED TO
(ING 2)

Fire Fighting

Flash Point Method:PMCC
Flash Point:>200F,>93C
Extinguishing Media:PROD WOULD NOT BE EXPECTED TO BURN UNLESS ALL WATER
IS BOILED AWAY. REMAINING ORGS MAY BE IGNITABLE. USE WATER (SUPDAT)
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:MAY EVOLVE NO*X UNDER FIRE CONDITIONS.

Accidental Release

Spill Release Procedures:SM LIQ SPILLS:CONTAIN W/ABSORB MATL, SUCH AS
CLAY, SOIL/ANY COMMERCIALLY AVAIL ABSORB. SCOOP RECLAIMED LIQ &
ABSORB INTO RECOVERY/SALVAGE DRUMS FOR DISP. CERCLA, 40 CFR 117,
302:NOTIFICATION OF SPILLS OF THIS PRODUCT IS NOT REQUIRED.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:MAY BE IRRITATING TO EYES, NOSE &
SKIN. KEEP CONTAINER TIGHTLY CLOSED. DO NOT TAKE INTERNALLY.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE
FOR EXPOSURE OF CONCERN . RESPIRATORY PROTECTION IS NOT NORMALLY
NEEDED.
Ventilation:GENERAL VENTILATION IS RECOMMENDED.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:IF CLOTHING IS CONTAMINATED, REMOVE CLOTHING &
THORO WASH AFFECTED AREA. LAUNDER CONTAMINATED CLOTHING BEFORE
REUSE.
Supplemental Safety and Health
PH:(NEAT)10. EXTING MEDIA:TO COOL CNTNRS EXPOSED TO FIRE. MATLS TO
AVOID:NITROUS ACID, ORG/INORG NITRITES/ATMS W/HIGH NITROUS OXIDE
CONCS. AVOID CONT W/STRONG OXIDIZERS (E.G., CHLORINE, PEROXIDES,
CHR OMATES, NITRIC ACID, PERCHLORATES, CONCOXYGEN, PERMANGANATES)
WHICH CAN GEN HEAT, FIRES, EXPLOS & RELS OF TOX FUMES.

Chemical Properties

pH:SUPDAT
Solubility in Water:COMPLETELY
Appearance and Odor:COLORLESS LIQUID; SLIGHT AMINE ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
N-NITROSAMINES, MANY ARE CANCER CAUSING AGENTS TO LAB ANIMALS, MAY BE
FORMED WHEN CERTAIN AMINES ARE MIXED W/ (SUPDAT)
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:IN EVENT OF COMBUSTION CO, CO*2, NO*X
MAY BE FORMED. DO NOT BREATHE SMOKE/FUMES. WEAR SUITABLE PROTECTIVE
EQUIPMENT.

Disposal

Waste Disposal Methods:IF PROD BECOMES WASTE, IT DOES NOT MEET CRITERIA
OF HAZ WASTE AS DEFINED UNDER RCRA 40 CFR 261, SINCE IT DOES NOT
HAVE CHARACTS OF SUBPART C,(I.E. D001-D017) NOR IS IT LISTED UNDER
SUBPART D. AS NON-H AZ LIQ WASTE, IT SHLD BE SOLIDIFIED BEFORE (ING
3)

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.